DIATERMO MB 400D HOSPITAL

https://www.euroserviziexport.com/web/image/product.template/6220/image_1920?unique=c207926

High-frequency electrosurgery can be used to perform monopolar and bipolar surgery simultaneously.

DUAL OPERATION
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations

CONTROLLED CUTTING PROCEDURES
- intensified cutting current for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current

CONTROLLED DUAL COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or foot pedal

EXTENSIVE BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic coagulation start and stop can be activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of contact impedance between patient's body and neutral plate continuously monitored by Skin Plate Electronic Control (SPEC)
- continuous monitoring of radiofrequency leakage current
- variation of mains voltage compensated automatically before starting power and radiofrequency delivery

CUSTOMISED PROCEDURES
- independent choice of coagulation currents and power levels for each of the two operators
- ten personal procedures that can be configured and immediately recalled

CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for controlled connections of argon plasma and fume extractor units

AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of malfunctions.

- AMBULATORY SURGERY
- GENERAL SURGERY
- PAEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNAECOLOGY
- NEUROSURGERY
- ORTHOPAEDICS
- OTORHINOLARYNGOLOGY
- PNEUMOLOGY
- UROLOGY
- VETERINARY - Maximum out power monopolar pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maxi 1 - Power cable 5 m
1 - Autoclavable handpiece with two buttons (30536)
5 - Cold ster. handpiece with two buttons (30551)
1 - Cable for plate (30559)
5 - Rem disposable plates (30493)
2 - HP watertight double footpad
3 - Short blade electrode

True 0.00 € 0.0 EUR 0.00 €

0.00 €

Request a quotation

This combination does not exist.