Diagnostic Tests - Laboratories

MULTITEST 7 DRUGS A GLASS -urine
MULTIDROGHE "BOTTLE" URINE TEST - 7 DRUGS - pack of 25

Rapid test for the simultaneous qualitative detection of multiple drugs and drug metabolites in human urine.
Detects the following substances: (MTD/MDMA)+<COC>+<AMP500>+<MET500>+<THC>+<MOP>.

- easy to use: no need to handle urine samples, just insert the key to start the test and get results in 5 min
- sealed urine cup: no spillage of urine
- special design: the sample does not contaminate the residual urine, which can be sent to a testing laboratory for further testing
- separate security key: only the laboratory technician can perform the test.

Professional use. User manual: GB, FR, IT, ES, PT, DE.

Accuracy: results have an accuracy = 75% for a sample with ±25% cut-off and 100% accuracy in negative values.

The test panel is firmly attached to the cup, protecting it from contamination.

Maximum shelf life 22 months.

DRUG / Cut off NG/ML / DETECTION TIME (Drug use prior to detection time is not measured)
MOP: 300 / 5-7 days
COC: 300 / 2-5 days
THC: 50 -
AMP: 500 / 2-5 days
MDMA: 500 / 5-7 days
MTD: 300 / 5-7 days
MET: 500 / 3-5 days
MULTITEST 12 DRUGS - urine panel
URINE DRUG TESTING FOR PROFESSIONAL USE

- MULTIDROGHE TEST 12 parameters - urine - pack of 25

Accurate results in 5 minutes for the following drugs: amphetamines, cocaine, marijuana (cannabis), methamphetamines, opiates, phencyclidine, barbiturates, benzodiazepines, ecstasy, morphine300, methadone, tricyclic antidepressants.

Cut-off levels in accordance with SAMHSA standards.

Manual: GB, FR, IT, ES, DE, PT, GR, Arabic. DRUG
- MOP
- CUT OFF: 300 ng/mL
- Detection time: 5-7 days
- COC
- CUT OFF: 150 ng/mL
- Detection time: 2-5 days
- THC
- CUT OFF: 50 ng/mL
- Detection time: 5-8 days
- AMP
- CUT OFF: 500 ng/mL
- Detection time: 2-5 days
CUP TEST DRUGS - 7 parameters + adulterants for 24570
Simply scan the test into the device (code 24570-24571) and get a complete analysis on your PC.
- automatic visual reading test analysis
- internal quality control system
- image acquisition, data management/export, results archive

Main benefits
- automatic - eliminates variability and subjectivity in result interpretation
- accurate - result guarantee compared to visual tests
- fast - scanning process takes 15-30 seconds
- flexible - different formats/menus, light weight, semi-portable, easy installation, Windows compatible
- suitable in occupational medicine for cost-effective screening of workers DRUGS
- MTD
- CUT OFF: 300 ng/mL
- Detection time: 5-7 days
- MDMA
- CUT OFF NG/M:L 500
- Detection time: 5-7 days
- MET
- CUT OFF NG/M:L 500
- Detection time: 3-5 days
- COC
- CUT OFF NG/M:L 300
- Detection time: 2-5 yy
MULTITEST 7 DRUGS IN A SHOT GLASS
It detects the following substances:
- MTD/MDMA
- COC
- AMP500
- MET500
- THC
- MOP

- Easy to use: no need to handle urine samples, just insert the key to start the test and get results in 5 min
- Sealed urine beaker: no spillage of urine
- The test panel is firmly attached to the beaker, protecting it from adulteration
- Advanced design: during the reaction the sample will not contaminate the residual sample. The same can be sent to a testing laboratory for further verification
- Separate security key: only the laboratory technician can perform the test

For professional use. - MOP
- CUT OFF: 300 ng/mL
- Detection time*: 5-7 days
- COC
- CUT OFF: 300 ng/mL
- Detection time*: 2-5 days
- THC
- CUT OFF: 50 ng/mL
- AMP
- CUT OFF: 500 ng/mL
- Detection time*: 2-5 days
- MDMA
- CUT OFF: 500 ng/mL
LIPID PROFILE CONTROL SOLUTION 2ml for 23983
Lipid control solution for Lux Reader (code 23983)

3 bottles of 2 ml each

One bottle for each parameter (total cholesterol, triglycerides, HDL).
INFLUENZA A/B TEST
The in vitro influenza A/B test is capable of detecting type A and B virus antigens (nucleoproteins) from respiratory samples. The test is designed to detect the various subtypes of influenza A, (H1N1, H3N2, H5N1, H5N3, H7N3, H9N2).
It is performed using nasal swabs that allow the necessary respiratory samples to be taken.
Easy to use with results in 10-15 minutes.
Includes rapid test device, swab, tube, reagent.

For professional use only.

ATTENTION: SHORT SHELF LIFE TEST.
Tests have a shelf life of 24 months from the date of manufacture. Stock may vary from 10 to 22 months.
ULCERA TEST - HELICOBACTER PYLORI - professional
ELICOBACTER PYLORI TEST - box of 40 tests

Rapid test for qualitative detection of Helicobacter Pylori antibodies in human whole blood, serum or plasma.
Easy to perform and interpret.

Rapid results in 10 minutes.
Includes 40 cassette tests, 40 droppers, 1 swab.
Multilingual box and manual: GB, FR, IT, ES, DE, HU.
Relative sensitivity: 96.8%; relative specificity: 93.0% and accuracy: 94.6%.

WARNING: SHORT SHELF LIFE TEST. The tests have a shelf life of 24 months from the date of manufacture. Stock may vary from 10 to 22 months.
ULCER TEST - HELICOBACTER PYLORI
As helicobacter pylori is the main cause of gastric ulcers, this easy-to-use test enables a rapid diagnosis (in about 10 minutes). Easy to perform and interpret.
Diagnosis in adults over 18 years of age.

For professional use.

Multilingual manual and box: GB, FR. IT, GR.

ATTENTION: TESTS WITH A SHORT SHELF LIFE.
Tests have 24 months shelf life from the date of production.
Stock may vary from 10 to 22 months
MALARIA TEST - professional
MALARIA TEST P.F. - pack of 40 tests

The malaria test is a rapid immunological chromatographic examination for the qualitative detection of Plasmodium falciparum in whole blood.
The test has been compared with traditional microscopic bloodstain analysis methods, the correlation between the two systems is greater than 99.0%.

The kit includes cassette test, reagent, disposable dispenser and multilingual manual (GB, FR, IT, ES). Lancets are not included.

For professional use.

ATTENTION: SHORT SHELF LIFE TESTS. Tests have a shelf life of 24 months from the date of manufacture. Stock may vary from 10 to 22 months.
PT/INR STRIPS for code 23926
PT test strips with chip.

Pack of 48 pieces.