Tens, Infrarex and accessories

TECARTERAPIA CR200 with 2 probes
TECAR THERAPY CR200 - with two probes

Diathermy, known as Tecar therapy (an acronym for Capacitive and Resistive Energy Transfer), is a therapy that stimulates the body's natural repair processes, shortening motor recovery times.

Diathermy, through electromagnetic energy-tissue interaction, produces an increase in temperature that occurs within the tissues in a uniform and controlled manner. This interaction results in the appearance of an ionic flow with a micro-hyperaemia that promotes the release of endogenous 'substances' (mainly cortisol and endorphins) to reduce pain, oedema and inflammation.

The new capacitive/resistive CR200 is a modern, high-performance device. Preset programmes make the device easy to use. In addition, the device can set parameters (power supply, therapy duration, resistive/capacitive mode) according to therapeutic needs.
It allows personalised programmes to be stored. This allows patient protocols to be easily consulted by therapists at any time. Equipped with a large graphic display to show therapy parameters and different operating modes.

Software languages: GB, FR, IT, ES.

Capacitive mode
Electrode coated with ceramic material (mobile) and return plate (fixed). Particularly suitable for soft tissue (muscle mass and lymphatic/vascular system). Advantages: specific intervention: easy control of the treated area.

Resistive mode
Non-isolated electrode (mobile) and return plate (fixed). Particularly suitable for tissues with greater resistance (bones, joints, tendons, ligaments, cartilage). Advantages: high level of diathermy; chronic disorders with fibrosis and degeneration.

- APPLICATIONS:
- Musculoskeletal disorders
- Chondropathy
- Coxatrosis
- Lumbago, pulbagia and chronic acute pain
- Ostroarticular pathologies

- 24 REHABILITATION PROGRAMMES:
Knee arthrosis, arthrosynovitis, bursitis, cervicalgia, patellar chondropathy, contusions, coxarthrosis, sprains, joint pain, oedema, epicondylitis, pityrocleitis, herniated spinal disc, plantar fasciitis, gonarthrosis, ACL, lymphoedema, back pain, meniscopathy, neuropathy, pariarthritis, muscle sprain, acute tendonitis, chronic tendonitis

- 10 SPORTS PROGRAMMES:
Muscle contractures, bruises, muscle strains, sprains, bruises, tendon injuries, surface massage, deep massage, muscle recovery
muscle sprain - Power supply: 110-240 V, 50/60 Hz
- Max. power: 260 W (100 ohm)
- Carrier frequency: 500 kHz
- Adjustable power: 0-100%.
- 7" graphic touch screen display
- Preset programmes, free memory
- 2 multifunctional probes (capacitive and resistive)
- Power cable
- 2 electrodes Ø35 mm (1 resistive + 1 capacitative) with 9.61 cm² effective working area
- 2 electrodes Ø60 mm (1 resistive + 1 capacitive) with 28.26 cm² effective area
250 W BULB for 28653
Replacement bulb 250W for infrared therapeutic lamp (cod. 28652 - 28653).
REPLACEMENT BULBS
7.5W replacement bulb for INFRAREX infrared therapy unit - 230 V - 50/60 Hz (code 28650).
Ni-Mh BATTERY for 28370/6/7, 28380/3
Ni-Mh BATTERY 4.8 V for 28370/6/7, 28380/2
CLIP ADAPTERS 2 mm -black
CLIP ADAPTERS 2 mm - black - pack of 10
CLIP ADAPTERS 2 mm - red
CLIP ADAPTERS 2 mm - red - pack of 10
CLIP ADAPTERS 4 mm -black
CLIP ADAPTERS 4 mm - black - pack of 10
CLIP ADAPTERS 4 mm -Red
CLIP ADAPTERS 4 mm - red - pack of 10
CABLES for tens 28342 - spare part
Pack of 2 cables, replacement for Tens GIMA 9 (cod. 28342).
BLUE AND YELLOW CABLES, male coupling 2mm - replacement for 28355/70/76-78/80/82
Pair of two lead cables (blue + yellow) 2mm male plug connection, for MIO-CARE models.