DIATERMO MB 300D HOSPITAL
High-frequency electrosurgery can be used to perform monopolar and bipolar surgery simultaneously.

DUAL OPERATION
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations

CONTROLLED CUTTING PROCEDURES
- intensified cutting current for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current

CONTROLLED DUAL COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or foot pedal

EXTENSIVE BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic coagulation start and stop can be activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of contact impedance between patient's body and neutral plate continuously monitored by Skin Plate Electronic Control (SPEC)
- continuous monitoring of radiofrequency leakage current
- variation of mains voltage compensated automatically before starting power and radiofrequency delivery

CUSTOMISED PROCEDURES
- independent choice of coagulation currents and power levels for each of the two operators
- ten personal procedures that can be configured and immediately recalled

CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for controlled connections of argon plasma and fume extractor units

AUTOMATIC SELF-DIAGNOSIS
- automatic self-diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of detected malfunctions.

- AMBULATORY SURGERY
- GENERAL SURGERY
- PAEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNAECOLOGY
- NEUROSURGERY
- ORTHOPAEDICS
- OTORHINOLARYNGOLOGY
- PNEUMOLOGY
- UROLOGY
- VETERINARY - Max. cutting power pure monopolar CUT: 300 W - 300 Ohm
- Max. cutting power monopolar CUT80%: 250 W - 300 Ohm
- Max. cutting power monopolar CUT60%: 200 W - 300 Ohm
- Power max. cut-off-coag monopolar CUT40%: 150 W - 300 Ohm
- Power 1 - Power cable 5 m
1 - Autoclavable handpiece with two buttons (30536)
5 - Cold ster. handpiece with two buttons (30551)
1 - Cable for plate (30559)
5 - Rem disposable plates (30493)
2 - HP watertight double footpad
3 - Short blade electrode
DIATERMO MB 400D HOSPITAL
High-frequency electrosurgery can be used to perform monopolar and bipolar surgery simultaneously.

DUAL OPERATION
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations

CONTROLLED CUTTING PROCEDURES
- intensified cutting current for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current

CONTROLLED DUAL COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or foot pedal

EXTENSIVE BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic coagulation start and stop can be activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of contact impedance between patient's body and neutral plate continuously monitored by Skin Plate Electronic Control (SPEC)
- continuous monitoring of radiofrequency leakage current
- variation of mains voltage compensated automatically before starting power and radiofrequency delivery

CUSTOMISED PROCEDURES
- independent choice of coagulation currents and power levels for each of the two operators
- ten personal procedures that can be configured and immediately recalled

CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for controlled connections of argon plasma and fume extractor units

AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of malfunctions.

- AMBULATORY SURGERY
- GENERAL SURGERY
- PAEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNAECOLOGY
- NEUROSURGERY
- ORTHOPAEDICS
- OTORHINOLARYNGOLOGY
- PNEUMOLOGY
- UROLOGY
- VETERINARY - Maximum out power monopolar pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maxi 1 - Power cable 5 m
1 - Autoclavable handpiece with two buttons (30536)
5 - Cold ster. handpiece with two buttons (30551)
1 - Cable for plate (30559)
5 - Rem disposable plates (30493)
2 - HP watertight double footpad
3 - Short blade electrode
DIATERMO MB 400 TOUCH
New-generation electrosurgical units that allow two surgeons to work simultaneously.

The radiofrequency generator is suitable for microsurgery and precision surgery in monopolar and bipolar modes.

Its simplicity allows it to be used without requiring prior training, which saves time.
Initial configuration and adjustment of settings during surgery can be easily selected from the large touch screen.

Performance, usability, design and reliability
- simultaneous activation of monopolar and bipolar mode
- impedance-dependent power control
- pedal and/or handpiece activated power supply
- neutral-patient electrode contact control
- cutting function under TUR saline solution
- modular cutting under humid conditions BLEND
- sealing of blood vessels up to 7 mm
- minimally invasive surgical treatment
- monopolar / bipolar functions
- automatic start/stop in bipolar mode
- adjustment of sound emission intensity

An intuitive and logical working environment
A particularly simple and intuitive working environment.
The horizontal correspondence between monitors, RGB indicator lights and connectors provide a clear and easily readable overview.
The large 9" capacitive touch screen with an elegant flat design ensures faster and more efficient cleaning in the operating theatre.

State-of-the-art device
Highly professional surgery with ergonomic and safe solutions.
The neutral electrode connection is constantly monitored: if a bipartite neutral plate is used, the device monitors the contact between the patient and the electrode.
The ability to switch functions and activate power delivery from the handpiece allows surgical procedures to be performed without diverting attention from the operating field.

Software
Developed to provide a simple, functional and intuitive working experience. With a single touch of a finger you can customise and save work settings, change the cutting or coagulation power and manage every function of the device.

Recommended for: GASTROENTEROLOGY, GENERAL SURGERY, NEUROSURGERY, ORTHOPAEDICS, PAEDIATRIC SURGERY, PLASTIC SURGERY, THORACIC SURGERY, TRANSURETHRAL RESECTION (TUR), UROLOGY

Can be used for: DERMATOLOGY, ENDOSCOPY, GYNAECOLOGY, ENTORhinolaryngology, PNEUMOLOGY, VASCULAR SURGERY, VETERINARY Max. power PURE CUT: 400 W - 300 Ohm
BLEND max. power: 250 W - 300 Ohm
Max. power ENHANCED: 250 W - 300 Ohm
Max. power FORCED COAG: 150 W - 150 Ohm
Max. power SOFT COAG: 150 W - 200 Ohm
Max. power FULGURATION: 100 W - 500 Ohm
Max. power BIPOL Neutral plate flexible steel with cable (30556+30560)
Power supply cable 5 m
Reusable handpiece with switches (30536)
MB tin foot pedal (30608)
3 blade electrodes - 16 cm
3 blade electrodes - 7 cm
3 ball electrodes Ø 4 - 6 cm
ELECTRODEPILATOR 400
The electrodepilator 400 is a device for permanent hair removal using the thermolytic method. Through the introduction of a needle, with radiofrequency current, into the hair follicle, the heating and consequent coagulation of the papilla is caused. Integrated with highly reliable electronic components, infinitely adjustable RF intensity and operating light.

Comes complete with foot pedal, depilation handpiece, depilation needle and power cable (2m). Radio frequency electro depilator: 1.9 ±10% MHz
Modulation: sinusoidal
Maximum power output: 7 ±2 Watt
Dimensions: 260x265xh 110 mm
Weight: 4 kg
Power supply: 115/230 V - 50/60 Hz switchable
Standards: CEI 62-39 Class: I-BF
MICROSURGERY HANDPIECE
Microsurgery handpiece for all GIMA diatherms and electrodepilators.
CABLE FOR PLACES (30555,30556,30566) - reusable
CABLE FOR STEEL-RUBBER PLATES codes 30555 and 30556
PROFESSIONAL HANDLE for electrolysis needles
Professional microsurgery handpiece for all Gima diatherms and electrodepilators.
BALLET K3 STAINLESS STEEL ELECTROLYSIS NEEDLES
STERILE SINGLE-USE BALLET NEEDLES FOR ELECTROLYSIS.
The Ballet needle is made with a very precise definition and has a mirror polished surface. Its rounded conical tip assists the operator in locating the follicle opening and glides smoothly to the very base of the follicle.

- K3 Needle - 0.075 mm (0.003")
- Stainless Steel: Ideal for patients with healthy, strong skin who respond well to electrolysis treatment.
BALLET K3 INSULATED ELECTROLYSIS NEEDLES
STERILE SINGLE-USE BALLET NEEDLES FOR ELECTROLYSIS.
The Ballet needle is made with a very precise definition and has a mirror polished surface. Its rounded conical tip assists the operator in locating the follicle opening and glides smoothly to the very base of the follicle.

- K3 needle - 0.075 mm (0.003")
- Isolated needle: recommended for patients with high sensitivity to electrolysis discomfort.
BALLET K2 STAINLESS STEEL ELECTROLYSIS NEEDLES
STERILE SINGLE-USE BALLET NEEDLES FOR ELECTROLYSIS.
The Ballet needle is made with a very precise definition and has a mirror polished surface. Its rounded conical tip assists the operator in locating the follicle opening and glides smoothly to the very base of the follicle.

- K2 Needle - 0.055 mm (0.002")
- Stainless Steel: Ideal for patients with healthy, strong skin who respond well to electrolysis treatment.