Products
Contact & Support
About us
Get Quote
0
0
Products
Contact & Support
About us
Get Quote
Products
GIMA
Listino Sito Export
Listino Sito Export
GIMA
AUDIOMETER SIBELSOUND 400A with W50 air software
SIBELSOUND 400A AIR SCREENING AUDIOMETER
Two-channel digital audiometers based on digital signal processing (DSP).
Fast and simple audiometric analysis of hearing threshold levels and screening tests, such as supraliminary tonal audiometric examinations (fowlerablb, tone decay, weber, luscher, ...).
Airway (tdh 39): 125 8,000 Hz or HF: 8,000 20,000 Hz with optional HDA 200
Levels: AC (10 to 120 dB HL) / bc (10 to 70 dB HL) / voice (10 to 100 dB HL) free field (10 to 80 dB HL)
Masking (manual or synchronised): nbn AC (10 to 100 dB HL ) nbn bc (10 to 70 dB HL ) white & vocal (10 to 100 dB SPL)
Tone: continuous, pulsed, alternating, amplitude modulation
Level increments: 5 (aaom), 1 or 5 (supra)
Frequency accuracy: ±1%/ level accuracy ±2% db spl
Automatic hearing loss calculation and diagnosis (council, imss mexico, eli, sal, klockhoff, moh, OTHERS ...)
Communication system
direct printing to USB printer or connection to W50 software
Direct USB connection to PC to W50 audiometry software for viewing, storing, transmitting, analysing and entering audiometric tests. It also allows data from other audiometers to be entered and shows automatic diagnosis (IMSS, ...). Compatible with Windows 7, 8.1 and 10 (32/64 bit).
Dimensions: 390x260x105 mm
Weight: 2.4 kg without accessories
Power supply: 100240 V, 50/60 Hz
Backlit alphanumeric LCD screen 2 lines of 16 characters
User manual GB, IT (available on request FR, ES) Audiometry type: 4 screening
TDH 39 air conduction
Intercom database: 150 tests
USB connection
Audiometry Software W50: optional
EARPIECE FOR AUDIOMETER PA5
Headset for PA5 audiometer use in adults.
SMALL BASIC DIAGNOSTIC AUDIOMETER aerial+masking
Piccolo is a portable audiometer that offers airborne, bone and speech audiometry capabilities. Piccolo can be controlled either from a Windows PC or, for the first time ever, from an iPad®.
Lightweight, compact in design, powerful, with user-friendly software and Noah connectivity, these features help make Piccolo the ideal choice for hearing care professionals.
Available in three models:
Basic (AEREA only) for use with PC
Plus (AEREA/OSSEA) for use with PC or iPad® (Aero version)
Speech (AEREA/OSSEA/VOCALE) for use with PC or iPad®.
Compatible with Windows 7, 8, 10
small and lightweight
powered by USB cable from computer
Italian production.
Software languages: GB, FR, IT, ES, DE, PL, PT, RU.
Manual on CD and quick guide: GB, FR, IT, ES, DE, PL, PT, NL. - Device type: PC-controlled
- Class EN 606451, ANSI 53.6: 4 screening
- Version: AC
- Masking: NBN
- Warble tone: Yes
- Pulsed tone: 0.5 Hz, 1 Hz, 2 Hz
- Frequency range: 125 8000 Hz
- Maximum intensity of AC signals: - TDH39 supra-aural headphones
- Patient response button
- Clip-on microphone for operator-patient communication
- Daisy Inventis patient management software with Maestro module
- Maestro module for Noah
- USB connection cable
- Medical power supply
AUDIOMETER PA5
The PA5 is a portable paediatric audiometer with air conduction, free field and visual stimulation. Thanks to the headset, it can also be used for regular screening of adults. The unique features of the PA5 assist clinicians in assessing the hearing behaviour of infants and children up to 24 months through specific tests.
AutoPalpebral Reflex (APR) Test
The APR test consists of triggering an eyelid reflex through some relatively loud sounds and can be performed on infants from the day they are born. It does not require the cooperation of the child.
Conditioned Orientation Response (COR) test
Based on the phenomenon called the orientation reflex, which consists of a natural reflex triggered by sound or visual stimulation. If the conditioning is effective, the child will look in the direction of the sound even before the visual stimulation is presented to it.
Visual Reinforcement Audiometry (VRA)
Extension and modification of COR, where collaboration with the child is less important. Not only the orientation and sound location reflex is accepted but also 4 other reactions: reflexes (body and face), search reactions, orientation and
spontaneous reactions.
Evaluation of the progression of auditory and audiometric responses
Various stimuli are presented with different intensities, frequencies, durations, direction of sound to provoke specific reactions in the child such as arousal, crying, surprise, direct localisation of sound.
Supplied with English manual and quick guide (GB, US, DE, FR, SE, IT, PT, DK, FI, ES, GR, CZ, PL, NL, NO, EE, HU, SL). - Frequencies: 500, 1000, 2000, 3000, 4000 Hz.
- Tones: high tones, NB and WN
- Intensity: 50 cm distance
20/3080 dB HL in 10 dB, for high-pitched tones and WN
10/2070 dB for NB
- Distance 16 cm: 10 dB intensity increase
- Weight: 360 g
- Dimensions
MAICO MA1 SCREENING AUDIOMETER WITH HEADPHONES
MAICO MA1 AUDIOMETER WITH HEADPHONES
Screening audiometer with a super-lightweight design, small enough to fit in the palm of your hand.
Ideal for quick screening purposes.
The device is capable of transmitting a pure tone to only one ear at a time.
The stimulation intensity range is from 15 to 50 dB HL in 5 dB level increments.
Test frequencies range from 500 to 4000 Hz.
Automatic ON/OFF function.
Supplied with DD45 audiometric headphones and 2 AA batteries.
Multilingual manual: GB, FR, IT. Test signal: pure tone (continuous)
Test frequencies: 500, 1000, 2000, 4000 Hz
Level increments: 5 dB
Stimulus intensity: 15 dB HL 50 dB HL
Accuracy: ± 4 dB
Distortion: less than 3%.
Dimensions: 6.4x15.3xh 2.3 cm
Weight: 115 g
Power supply
DIAGNOSTIC AUDIOMETER SMALL PLUS air + osmosis + masking
Piccolo is a portable audiometer that offers airborne, bone and speech audiometry functionality. Piccolo can be controlled either from a Windows PC or, for the first time ever, from an iPad®.
Lightweight, compact in design, powerful, with user-friendly software and Noah connectivity, these features help make Piccolo the ideal choice for hearing care professionals.
Available in three models:
Basic (AEREA only) for use with PC
Plus (AEREA/OSSEA) for use with PC or iPad® (Aero version)
Speech (AEREA/OSSEA/VOCALE) for use with PC or iPad®.
Compatible with Windows 7, 8, 10
small and lightweight
powered by USB cable from computer
Italian production.
Software languages: GB, FR, IT, ES, DE, PL, PT, RU.
Manual on CD and quick guide: GB, FR, IT, ES, DE, PL, PT, NL. - Device type: PC-controlled
- Class EN 606451, ANSI 53.6: 3 diagnostic
- Version: AC,BC
- Masking: NBN
- Warble tone: Yes
- Pulsed tone: 0.5 Hz, 1 Hz, 2 Hz
- Frequency range: 125 8000 Hz
- Maximum signal intensity - TDH39 supra-aural headphones
- Bone vibrator B71
- Patient response button
- Clip-on microphone for operator-patient communication
- Daisy Inventis patient management software with Maestro module
- Maestro module for Noah
- USB connection cable
AMPLIVOX 240 DIAGNOSTIC AUDIOMETER
DIAGNOSTIC AUDIOMETER AMPLIVOX 240 airway, boneway, masking
Affordable diagnostic audiometer with USB connectivity, ideal for use in both the office and home visits.
threshold storage functionality
single tone, pulsed or frequency modulated preset
11 frequencies from 125 to 8,000 Hz (AC), 250 to 8,000 Hz (BC)
range 10 to 120 dBHL (AC), 10 to 70 dBHL (BC), 90 dBHL max (250 to 4,000 Hz) masking insert output
automatic AC test function
Supplied with audiometric headset, bone vibrator, patient response button, audiogram cards (pack of 50), power supply, carrying case and manual (GB, IT, ES, on request FR, SE, RU, PT).
2 lines of 24 characters on backlit display.
Weight: 735 g
Dimensions: 270x175x68 mm
Power supply: 100240 V, 5060 Hz.
MASKING INSERT
Masking insert.
Accessory for:
DIAGNOSTIC AUDIOMETER AMPLIVOX 240 airway, bone, masking (cod. 53551)
MAICO MA27 air conduction SCREENING AUDIOMETER
MAICO MA27 SCREENING AUDIOMETER
Basic screening audiometer with lightweight hard case.
It has 11 frequencies, integrated carrying handle and compartment for headphones and accessories.
Robust, accurate and reliable, with large control knobs for easy adjustment of frequency and stimulus intensity.
Selectable screen languages: GB, FR , IT , ES, DE.
Supplied with AC DD45 audiometric headset, audiogram pad and power supply.
Multilingual manual: GB, FR , IT , ES, DE, PL, RU . Screen: 38.1x76.2 mm, monochrome
Level increments: 5 or 1 dB
Stimulus intensity: 10 dB HL 100 dB HL
Test signal: pure tone and frequency modulated (pulsed and continuous)
Test frequencies: 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000,
SOUNDPROOFED SHELLS
Soundproofed shells for audiometry
Accessory for:
SCREENING AUDIOMETER AMPLIVOX 116 airway (cod. 53550)
DIAGNOSTIC AUDIOMETER AMPLIVOX 240 airway, bone, masking (cod. 53551)
80
81
82
83
84
We use cookies to provide you a better user experience on this website.
Cookie Policy
Only essentials
I agree