Optional SOFTWARE for models sold until March 2023
W50 software for audiometry.

Compatible with Windows 7, 8.1 and 10 (32/64 bits).

Optional for SIBELSOUND 400A (Code 33623) and 400AOM (Code 33624) audiometers.
TIMPANOMETER MT 10 with IPSI reflections
Professional portable tympanometer for fast and accurate testing. Effective and economical.

Objective analysis: fast and easy to use, it produces objective measurements that cannot be obtained with the otoscope alone.

Quick and easy tympanograms: results can be obtained easily and quickly without the need for a response from the patient, which is a great advantage when dealing with difficult patients or children.

Clinical application: suitable for diagnostic use as a tympanometer.

Capable of recording reflex responses and providing details.
The MT10 makes it possible to detect otitis media, perforation of an eardrum, cholesteatoma and clear neurological disorders. It is also possible to check tympanostomy tubes and verify results following medical treatment.

Ipsilateral acoustic reflexes: four acoustic reflex tests can be performed for each ear using a fixed or automatic intensity selection of 500, 1000, 2000 and 4000 Hz for each. The characteristics of the reflexes can be viewed on the screen.

The MT10 can store test results for up to 30 patients. This makes it possible to examine a large group of patients and subsequently print out their data.

PC integration via an infrared USB interface and optional software.

Supplied with handle, set of 139 disposable caps (mixed sizes) and 4 x 1.5 V batteries, manual in GB, DE, FR, IT, ES, SE, GR, PT, DK, FI, CZ, PL, LT, EE, HU, NL, NO, IS, RO, MK.

Internal software: GB, FR, DE.

The MT10 is ergonomically designed but also offers the possibility of using the included handle to make it even more stable and lightweight as it can be rested on the arm during measurement.

Dimensions: 19 x 8 x v4 cm without probe (length with probe 22.5 cm)
Weight: 285 g without battery Timpanometry
- Analysis performed: peak compliance, peak pressure, gradient, equivalent ear canal volume
- Probe tone: 226 Hz
- Pressure levels: +200 daPa to 400 daPa
- Ear volume measurement range: 0.2 ml
SIBELSOUND 400SUPRA AUDIOMETER
SIBELSOUND 400SUPRA CLINICAL AUDIOMETER airway + bone way + masking + supraliminary test + W50 software + Intercom kit

Two-channel digital audiometers based on digital signal processing (DSP).
Quick and easy audiometric analysis of hearing threshold levels and screening tests, such as supra-liminal tonal audiometric tests (fowlerablb, tone decay, weber, luscher, ...).
Airway (tdh 39): 125 8,000 Hz or HF: 8,000 20,000 Hz with optional HDA 200
Levels: AC (10 to 120 dB HL) / bc (10 to 70 dB HL) / voice (10 to 100 dB HL) free field (10 to 80 dB HL)
Masking (manual or synchronised): nbn AC (10 to 100 dB HL ) nbn bc (10 to 70 dB HL ) white & vocal (10 to 100 dB SPL)
Tone: continuous, pulsed, alternating, amplitude modulation
Level increments: 5 (aaom), 1 or 5 (supra)
Frequency accuracy: ±1%/ level accuracy ±2% db spl
Automatic hearing loss calculation and diagnosis (council, imss mexico, eli, sal, klockhoff, moh, OTHERS ...)

Communication system
direct printing to USB printer or connection to W50 software
Direct USB connection to PC to W50 audiometry software for viewing, storing, transmitting, analysing and entering audiometric tests. It also allows data from other audiometers to be entered and shows automatic diagnosis (IMSS, ...). Compatible with Windows 7, 8.1 and 10 (32/64 bit).

Dimensions: 390x260x105 mm
Weight: 2.4 kg without accessories
Power supply: 100240 V, 50/60 Hz
Backlit alphanumeric LCD screen 2 lines of 16 characters
User manual GB, IT (available on request FR, ES) Audiometry type: 2 clinic
TDH 39 air conduction
B71 Bone Conduction
Narrow band masking and speech noise
Sisi test
Supraliminal test
Speech audiometry
Intercom kit (headset + microphone)
Music frequency
Intercom database: 1000 tests
BELL PLUS DIAGNOSTIC AUDIOMETER airborne + osmosis + masking
BELL PLUS DIAGNOSTIC AUDIOMETER air + bone + masking + DAISYMAESTRO software

Bell is a basic diagnostic audiometer for fast and accurate aerial and bone audiometry.

Ease of use, fast and reliable 'automatic examination' mode, userfriendly interface and easy portability make Bell the ideal tool for private clinics, multi-specialist practices and occupational medicine applications.

Pure tone audiometry in AC/BC
HughsoneWestlake automatic threshold test
Colour graphic display
Internal memory for 100 patients
Economical solution
Supplied with air conduction cuff and bone vibrator.
Made in Italy.


Manual: GB, FR, IT, ES, DE, PT.

Maestro software interface: The Maestro module is the software related to the Bell Plus audiometer. By connecting the device to a PC via USB, it is possible to view real-time examination results and download data. With this software it is also possible to fully control the functions of the audiometer. - Device Type: Hybrid Audiometer
- Class EN 606451, ANSI 53.6: 3 diagnostic
- Version: AC/BC
- Masking: NBN, WN
- Insertion earpiece for masking Yes
- Warble tone: Yes
- Pulsed tone: 0.5 Hz, 1 Hz, 2 Hz
- Freq range - TDH39 supra-aural headphones
- B71 Bone Vibrator
- Patient response button
- Plastic cover
- Medical power supply
- User's manual
EXTRA ISOLATION HEADPHONES
Noise attenuator for airborne headphones.
AIRWAY HEADPHONES for 336103361233630
Replacement air conduction headphones for audiometers 33610, 33612.
TIMPANOMETER MT 10
Professional portable tympanometer for fast and accurate testing. Effective and economical.

Objective analysis: fast and easy to use, it produces objective measurements that cannot be obtained with the otoscope alone.

Quick and easy tympanograms: results can be obtained easily and quickly without the need for a response from the patient, which is a great advantage when dealing with difficult patients or children.

Clinical application: suitable for diagnostic use as a tympanometer.

The MT10 can store test results of up to 30 patients. This makes it possible to examine a large group of patients and subsequently print out their data.

PC integration via an infrared USB interface and optional software.

Supplied with handle, set of 139 disposable caps (mixed sizes) and 4 x 1.5 V batteries, manual in GB, DE, FR, IT, ES, SE, GR, PT, DK, FI, CZ, PL, LT, EE, HU, NL, NO, IS, RO, MK.

Internal software: GB, FR, DE.

The MT10 is ergonomic but also offers the possibility of using the included handle to make it even more stable and lighter as it can be rested on the arm during measurement.

Dimensions: 19 x 8 x v4 cm without probe (length with probe 22.5 cm)
Weight: 285 g without battery Timpanometry
- Analysis performed: peak compliance, peak pressure, gradient, equivalent ear canal volume
- Probe tone: 226 Hz
- Pressure levels: +200 daPa to 400 daPa
- Ear volume measurement range: 0.2 ml
USB+SOFTWARE ADAPTER for 33665/6
USB interface adapter with software for portable impendence tympanometer MT10.
PORTABLE THERMAL PRINTER for 33665/6
Sanibel MPTII portable thermal printer for portable impendence tympanometer MT10.
ELECTRONIC BOEL TEST
The BOEL test is the only screening instrument used by paediatricians to judge the hearing faculties of children and allows early verification of the response to a sound stimulus as early as 6 to 10 months of age. The device is based on the classic BOEL test both in terms of its ergonomic shape (it fits in the palm of the hand) and the sound standards of the BOEL test bells. In fact, the two sound stimuli reproduce a low-frequency deaf sound around 125150 Hz and a high-frequency high-pitched sound around 5.05.1 kHz in a manner perfectly equivalent to what is reproduced by the BOEL test bells (86dBA, 96dBA). This makes it possible to test the child's response on these highly significant thresholds. The device is handy, lightweight, battery-powered and has only two buttons for selecting the two test frequencies. For the original Boel's test, we recommend the use of optometric pencils to capture the child's attention, see code 31319.