Diagnostic Tests - Laboratories

MULTICAREIN - Italian
MULTICAREIN - Italian

Supplied with nylon pouch, 5 cholesterol strips, 5 safety lancets, quick guide (GB, FR, IT, ES, PT, GR, PL, HU) and IT manual.

Multi-parameter diagnostic device for periodic self-monitoring of risk factors: cholesterol, triglycerides and glucose. Portable for easy testing and quick results.
Accurate, with Amperometric Technology for glucose and Reflectometric Technology for cholesterol and triglycerides.
Switchable mg/dL - mmol/L
Multi-language box: GB, FR, IT, ES, GR, PT, PL, HU, RU and selectable internal software: GB, IT. - Electrochemical glucose
Measuring range: 10-600 mg/dL - 0.6-33.3 mmol/L
Measurement time: 5"
Blood sample: 0.5 µl

- Cholesterol
Measuring range: 130-400 mg/dL - 3-10.2 mmol/L
Measuring time: 30"-60"
Blood sample: 10 µl

-
CHOLESTEROL CONTROL SOLUTION for 23965/66/67, 24150/1/2
Control solution for MULTICAREIN devices.
TRIGLYCERIDES CONTROL SOLUTION for 23965/66/67, 24150/1/2
Control solution for MULTICAREIN devices.
COMPLETE GLUCOMETER KIT GIMA mmo/L - GB, FR
On Call Plus II glucose meter kit - mmol/L

Languages box, manual: GB , FR

Kit includes 10 strips, chip code, counter solution, 10 sterile lancets, lancing pen, transparent cap (for forearm or palm testing), carrying case, user manual.

SOFTWARE FOR MULTICARE 'IN' AND MULTICAREIN GB,FR,IT,ES
SOFTWARE + CABLE FOR MULTICAREIN - GB , EN - optional

Operating system: Windows XP, Windows 7, 8, 10, Vista, 16 Mb Ram.
GIMA GLUCOMETER COMPLETE KIT mg/dl - GB, FR, ES, PT
GIMA glucometer kit

- Complete kit including 10 strips, control solution, 10 sterile lancets, lancing pen, transparent cap (for forearm or palm testing), carrying case, user manual.

Accurate and reliable glucose meters for self-diagnosis and professional use. Extensive clinical studies demonstrate the accuracy of the Gima glucose testing system, developed by Acon, with fresh capillary, venous and neonatal blood samples.

Compliant with ISO15197:2013/EN ISO15197:2015.

Box and manual language: GB, FR, ES, PT. Technology: Biosensor/Electrochemistry, Glucose Dehydrogenase (GDH-FAD)
Calibration method: No coding
Calibration results: Plasma-equivalent
Test time: 5 seconds
Sample volume: 0.6µL
Sample type: Fresh whole blood (capillary, venos
MULTICAREIN - English
MULTICAREIN - English

Supplied with nylon pouch, 5 cholesterol strips, 5 safety lancets, quick guide (GB, FR, IT, ES, PT, GR, PL, HU) and GB manual.

Multi-parameter diagnostic device for periodic self-monitoring of risk factors: cholesterol, triglycerides and glucose. Portable for easy testing and quick results.
Accurate, with Amperometric Technology for glucose and Reflectometric Technology for cholesterol and triglycerides.
Switchable mg/dL - mmol/L
Multi-language box: GB, FR, IT, ES, GR, PT, PL, HU, RU and selectable internal software: GB, IT. - Electrochemical glucose
Measuring range: 10-600 mg/dL - 0.6-33.3 mmol/L
Measurement time: 5"
Blood sample: 0.5 µl

- Cholesterol
Measuring range: 130-400 mg/dL - 3-10.2 mmol/L
Measuring time: 30"-60"
Blood sample: 10 µl

-
SQUARE SAFETY LANCES - needle 21G - automatic
Easy-to-use and practical safety lancets to meet various capillary blood sampling needs.

- SQUARE SAFETY LANCETS
- Colour: orange
- Penetration depth: 2.2 mm
- Gauge: 21G
- Flow: 40-50 µI
- Pungidito: SI
- Glucose: YES
- Haematocrit: YES
- Bleeding: High

- Disposable: built-in self-destruct mechanism prevents reuse of the device

- automatic needle retraction after single use eliminates the risk of accidental injury and contamination

- guaranteed sterilisation: the lancet is gamma-sterilised and the needle tip is protected by a sterility tab until use, thus ensuring a long shelf life from the date of manufacture

Multi-language box and instructions: GB, FR, IT, ES, PT, DE, PL, CZ, SE, RO, SK, NL, DK, FI, EE, HR, HU, LT, LV, NO, SI, BG, RU, GR, Arabic
AUTOMATIC ROUND SAFETY LANCES - needle 21G
Easy-to-use and practical safety lancets to meet various capillary blood sampling needs.

- ROUND SAFETY LANCETS
- Colour: yellow
- Penetration depth: 2.2 mm
- Gauge: 21G
- Flow: 40-60 µI
- Pungidito: SI
- Glucose: YES
- Haematocrit: YES
- Bleeding: High

- Disposable: built-in self-destruct mechanism prevents reuse of the device

- automatic needle retraction after single use eliminates the risk of accidental injury and contamination

- guaranteed sterilisation: the lancet is gamma-sterilised and the needle tip is protected by a sterility tab until use, thus ensuring a long shelf life from the date of manufacture

Multi-language box and instructions: GB, FR, IT, ES, PT, DE, PL, CZ, SE, RO, SK, NL, DK, FI, EE, HR, HU, LT, LV, NO, SI, BG, RU, GR, Arabic
SQUARED AUTOMATIC SAFETY LANCES - needle 23G
Easy-to-use and practical safety lancets to meet various capillary blood sampling needs.

- SQUARE SAFETY LANCETS
- Colour: white
- Penetration depth: 1.8 mm
- Gauge: 23G
- Flow: 20-40 µI
- Pungidito: SI
- Glucose: YES
- Haematocrit: YES
- Bleeding: Medium

- Disposable: built-in self-destruct mechanism prevents reuse of the device

- automatic needle retraction after single use eliminates risk of accidental injury and contamination

- guaranteed sterilisation: the lancet is gamma-sterilised and the needle tip is protected by a sterility tab until use, thus ensuring a long shelf life from the date of manufacture

Multi-language box and instructions: GB, FR, IT, ES, PT, DE, PL, CZ, SE, RO, SK, NL, DK, FI, EE, HR, HU, LT, LV, NO, SI, BG, RU, GR, Arabic