PATIENT CIRCUIT (valve + tube)
Patient circuit (valve + corrugated tube) for SPENCER electronic respirator

- Code 34006 SPENCER 170 NXT ELECTRONIC Breathing apparatus
- Code 34007 SPENCER 170 NXT ELECTRONIC Breathing apparatus KOMPAK
- No. 34009 SPENCER 190 NXT ELECTRONIC Breathing apparatus
SPENCER 118 NXT KOMPAKT AUTOMATIC FAN
Pneumatic lung ventilator for non-invasive ventilation of adult and paediatric patients.
The pneumatic mode of operation allows for a significant reduction in maintenance costs associated with electrical requirements and safety regulations.

Total absence of risk of electric shock generated by the device.
Protection against accidental switch-on and AIR MIX levers.
Colour coded hand-vacuum meter for immediate display of pressure in the patient circuit.
Lateral positioning of the medical gas inlet and outlet makes connection and disconnection easy and offers greater protection for the elements
connected to the device. High-contrast knob adjustment background for better identification of settings.
Compact and lightweight aluminium frame.
Positioning and shape of the adjustment knobs facilitating the setting of ventilation parameters under all operating conditions.
Non-constant l/E ratio makes ventilation management more versatile.
The presence of a single ventilation mode makes it simple and easy to use.

Supplied with alarm system required by EN 794-3 standards.
Medical Class II B device. Device according to Dir.93/42/CEE.
Made in Italy.

Kompak respirator with case.
The case contains the ventilator and oxygen cylinder with pressure regulator, ready to use. - Operation: 100% pneumatic
- Ventilation mode: Controlled (VC - CMV)
- Respiratory rate: 10 to 70 breaths/min.
- Inspiration-exhalation phase time: 1:2.0 ±0.3 at 10 bpm - 1:1.5 ±0.3 at 70 bpm
- Frequency: 10 to 70 bpm
- Fluss - Patient Circuit (corrugated tube with non-rebreathing valve)
- Adult mask
- Anti-bacterial filter
- Oxygen tube 100 cm - UNI adapter
- Oxygen cylinder 2 l
- Guedel tube, tongue depressor
- Pressure reducer
-
SPENCER 118 NXT AUTOMATIC FAN
Pneumatic lung ventilator for non-invasive ventilation of adult and paediatric patients.
The pneumatic mode of operation allows for a significant reduction in maintenance costs associated with electrical requirements and safety regulations.

Total absence of risk of electric shock generated by the device.
Protection against accidental switch-on and AIR MIX levers.
Colour coded hand-vacuum meter for immediate display of pressure in the patient circuit.
Lateral positioning of the medical gas inlet and outlet makes connection and disconnection easy and offers greater protection for the elements
connected to the device. High-contrast knob adjustment background for better identification of settings.
Compact and lightweight aluminium frame.
Positioning and shape of the adjustment knobs facilitating the setting of ventilation parameters under all operating conditions.
Non-constant l/E ratio makes ventilation management more versatile.
The presence of a single ventilation mode makes it simple and easy to use.

Supplied with alarm system required by EN 794-3 standards.
Medical Class II B device. Device according to Dir.93/42/CEE.
Made in Italy. - Operation: 100% pneumatic
- Ventilation mode: Controlled (VC - CMV)
- Respiratory rate: 10 to 70 breaths/min.
- Inspiration-exhalation phase time: 1:2.0 ±0.3 at 10 bpm - 1:1.5 ±0.3 at 70 bpm
- Frequency: 10 to 70 bpm
- Fluss - Patient Circuit (corrugated tube with non-rebreathing valve)
- Adult mask
- Anti-bacterial filter
- Oxygen tube 100 cm - UNI adapter
- Manual: GB, IT (on request FR, ES, DE, PT)
SPENCER KOMPAK 170 ELECTRONIC RESPIRATOR
SPENCER 170 NXT KOMPAK ELECTRONIC RESPIRATOR

Kompak respirator with case: the case contains the 170 NTX respirator and oxygen cylinder with pressure regulator, ready to use.

Electronic lung respirators for non-invasive ventilation of adults and paediatric patients.

- selection lever for protection against accidental activation of the AIR mix
- colour coded pressure gauge for easy identification of pressure range
- placement of inlet and outlet ports on the side of the device, making it easier to connect and disconnect and offering greater protection to items connected to the device
- control knobs on a high-contrast background for better identification of set values
- compact and lightweight aluminium frame
- the position and shape of the control knobs allow parameters to be set more easily and in all operating conditions
- constant I/E ratio
- alarms for monitoring and management of ventilation devices

Italian production. - Operation: Electronic
- Frequency: 5 to 40 BPM
- Alarms:
- High pressure
- Pneumatic power supply
- Low battery
- Flow: 2 to 20 l/min
- I/E ratio: 1:2
- Oxygen concentration: 60% to 100% patented system
- Val - Patient circuit (corrugated tube with non-rebreathing valve)
- Power cable
- Oxygen tube
- Manual: GB, IT, on request FR, ES, DE, PT
- Oxygen cylinder 2 l, pressure reducer, carrying case
- Masks
SPENCER 170 ELECTRONIC RESPIRATOR
SPENCER 170 NXT ELECTRONIC RESPIRATOR

Electronic lung ventilators for non-invasive ventilation of adults and paediatric patients.

- selection lever for protection against accidental activation of the AIR mix
- colour coded pressure gauge for easy identification of pressure range
- placement of inlet and outlet ports on the side of the device, making it easier to connect and disconnect and offering greater protection to items connected to the device
- control knobs on a high-contrast background for better identification of set values
- compact and lightweight aluminium frame
- the position and shape of the control knobs allow parameters to be set more easily and in all operating conditions
- constant I/E ratio
- alarms for monitoring and management of ventilation devices

Italian production. - Operation: Electronic
- Frequency: 5 to 40 BPM
- Alarms:
- High pressure
- Pneumatic power supply
- Low battery
- Flow: 2 to 20 l/min
- I/E ratio: 1:2
- Oxygen concentration: 60% to 100% patented system
- Val - Patient circuit (corrugated tube with non-rebreathing valve)
- Power cable
- Oxygen tube
- Manual: GB, IT, on request FR, ES, DE, PT
- Adult mask
- Battery
- UNI adapter
BATTERY FOR FAN 170 cod. 34030, 34031
Replacement battery 12 V DC for SPENCER electronic respirator

- No. 34006 SPENCER 170 NXT ELECTRONIC Breathing apparatus
- No. 34007 SPENCER 170 NXT ELECTRONIC Breathing apparatus KOMPAK
- No. 34009 SPENCER 190 NXT ELECTRONIC Breathing apparatus
SPENCER 190 ELECTRONIC RESPIRATOR
SPENCER 190 NXT ELECTRONIC RESPIRATOR

Electronic lung ventilators for non-invasive ventilation of adults and paediatric patients.

- selection lever for protection against accidental activation of the AIR mix
- colour coded pressure gauge for easy identification of pressure range
- placement of inlet and outlet ports on the side of the device, making it easier to connect and disconnect and offering greater protection to items connected to the device
- control knobs on a high-contrast background for better identification of set values
- compact and lightweight aluminium frame
- the position and shape of the control knobs allow parameters to be set more easily and in all operating conditions
- constant I/E ratio
- alarms for monitoring and management of ventilation devices

Features 190 NXT respirator
- LED for respiratory monitoring
- three ventilation modes
- CMV: mandatory inflation is started according to the set parameters
- TVM: inflation is only started according to set parameters if activated by the patient
- AC/AV. ensures that inflation is started at intervals determined by set parameters unless triggered by a previous patient-activated event.

Made in Italy. - Operation: Electronic
- Frequency: 5 to 40 BPM
- Alarms:
- High pressure
- Low pressure
- Apnoea
- Pneumatic power supply
- Low battery
- Flow: 2 to 20 l/min
- I/E ratio: 1:2
- Oxygen concentration: 60% to 10 - Patient circuit (corrugated tube with non-rebreathing valve)
- Power cable
- Oxygen tube
- Manual: GB, IT, on request FR, ES, DE, PT
- Adult mask
- Battery
- UNI adapter
FAN HOSE
117 cm hose for SPENCER electronic respirator

- Code 34006 SPENCER 170 NXT ELECTRONIC Breathing apparatus
- Code 34007 SPENCER 170 NXT ELECTRONIC Breathing apparatus KOMPAK
- Code 34009 SPENCER 190 NXT ELECTRONIC BURNER
- Code 34016 AUTOMATIC BURNER SPENCER 118 NXT
- No. 34017 SPENCER 118 NXT AUTOMATIC BREATHERS KOMPAK
BATTERY PACK FOR 34006, 34007, 34009
BATTERY PACK - replacement